PULLEY LOAD CELL

Features: Compact, excellent resolution. Easy to assemble, high resonant frequency. Protection against overloads.

Applications:coil winding machines, winding machines, unwinding machines, wire tensioner for any applications that have to measure the tension of wires, tapes, optical fibres, tessil wires, etc.


Zoom Click to enlarge image

Pulley load cells P32 Pulley load cells P32 Schema Pulley load cells P32 Montaggio

Technical Specifications

MaterialAluminium
Nominal load2.5, 5, 10, 25, 50, 100, 200 N
Limit load300 % F.S.
Breaking load500 % F.S.
Supply voltageMaximum 18 V dc
Sensitivity0,6 - 1 mV/V
Output tollerance0,2 % F.S.
Zero tollerance1 % F.S.
Linearity0,1 % F.S.
Hysteresis0,2 % F.S.
Reapeatability0,2 % F.S.
Input resistance350-360 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 54
Standard cable length3 m – 4 x 0,15 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeSHIELDED CABLE PVC 4C R3 4X0,15
Length3 m (body lead cell not connected shield)
Red+ IN
Black- IN
Green+ OUT
White- OUT
Connections  Pulley load cells P32

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means